Industrial Modules
|
We manufacture a qualitatively superior range of industrial modules that have been designed in accordance with the needs of our client. Fabricated using premium quality raw material, these industrial modules as integration pressurizing module, recirculatory modules are widely employed in biological labs and research institutes.
|
Pressurizing Modules  | Kleanzone pressurizing modules food filtered, bacteria free air to build up and maintain positive pressure in Class M 5.5 Clean areas. These pressurizing module are upgradation devices and require judicious selection and use. Technical Specifications:
- Cleanliness - Class 100
- Particle retention - 0.3 micron
- Velocity - 100FPM + 20%
- Illumination - 4 ft. 40w with diffuser
- Noise level - 60-65
- Decibels standard - FED 209E
- Power supply - 220v Single phase
Validation:
- Particle counts testing
- HEPA filter leak testing (D.O.P)
- Air velocity testing
- Room pressurization testing
- Temperature and humidity testing
- Light intensity testing
- Noise level testing
- Airflow Air Pattern
- General laminar airflow, Biosafety
- Cabinets servicing etc.
Testing Standards:
- IES - RP - CC - OO2 (Institute of Environmental Science - Recommended practice - 002)
- US - Federal Standard 209 and ISO 14644 -1 -1999.
|  | Request for full product details and quotation |
Integration Pressurising Module  | AC integrated class 100 integration pressurizing module to pressurize and sustain the clean air with HEPA filter of 0.3 micron, pre filter, motor blower assembly. It delivers cooled and filtered air into the room. In return air duct having one pre filter of 5 micron, 5%fresh air provision with dampers for control the fresh air quantity. Technical Specification:
- Air changes / Hour - 40
- Temp - 24.c
- Humidity - 45-60%
- Class-10,000
- Noice level - 65 decibels +/-5
- Standard - FED STD 209E.
|  | Request for full product details and quotation |
Recirculatory Modules  | Kleanzone floor standing or ceiling suspended recirculatory modules continually filter room air to reduce the airborne microflora and ultrafines. In addition they can provide a primary class M. 3.5 work environment for sub-critical tasks. Technical Specification :
- Cleanliness - Class 100
- Particle retention - 0.3 micron
- Velocity - 100FPM + 20%
- Illumination - 4 ft. 40w with diffuser
- Noise level - 60-65
- Decibels standard - FED 209E
- Power supply - 220v single phase
|  | Request for full product details and quotation |
Sterile OT  | This sterile operation theater system is unidirectional and delivers air flow over the operating table of 300cfu air changes per hour. A bacterial count of 10 cfu or less per cubic meter at the wound site is achieved. Advantages: - Prevent contamination of the open wound
- Isolate the operative site from the surrounding unsterile physical environment
- Create and be performed safely
|  | Request for full product details and quotation |
|
What We Offer

|